1
00:00:00,060 --> 00:00:05,630
So let us try to consider how you handled the situation when you have multiple interests in your system,

2
00:00:05,640 --> 00:00:05,940
right?

3
00:00:06,360 --> 00:00:10,920
So what we're going to do is we will be utilizing and into from two different sources.

4
00:00:10,920 --> 00:00:15,960
One of the source will be the slate, which either source will be push button, right?

5
00:00:16,050 --> 00:00:21,990
We already have created a new project utilizing a diesel script, and we also have our data processing

6
00:00:21,990 --> 00:00:22,380
system.

7
00:00:22,650 --> 00:00:28,560
So first, we will add all the necessary pool to housing processing system that allow us to interface

8
00:00:28,950 --> 00:00:31,470
the sleeve IP with disgusting system, right?

9
00:00:31,470 --> 00:00:35,970
So to do that, we just need to customize our zinc processing system.

10
00:00:36,000 --> 00:00:36,390
OK.

11
00:00:36,840 --> 00:00:39,930
First, we go to special configuration in a gender gap.

12
00:00:40,270 --> 00:00:44,430
OK, we have a clock reset, which we need to enable.

13
00:00:44,490 --> 00:00:44,740
OK.

14
00:00:44,760 --> 00:00:48,390
This will be providing a reset for all the sleep over it.

15
00:00:48,690 --> 00:00:55,580
OK, we go to any sign on unsecure enablement and dare we enable anemic zero interface?

16
00:00:55,590 --> 00:00:57,090
This is the second thing that we do.

17
00:00:57,450 --> 00:01:01,320
Then we go to a clock configuration and we add APL fabric.

18
00:01:01,520 --> 00:01:01,690
Right.

19
00:01:01,740 --> 00:01:08,180
So let's just stick to our default value of 50 megahertz same legal right to literally distribute.

20
00:01:08,970 --> 00:01:11,470
Now we are ready to add this right.

21
00:01:12,090 --> 00:01:13,230
So let me just go ahead.

22
00:01:14,390 --> 00:01:15,860
And search for UPI.

23
00:01:15,890 --> 00:01:16,190
Right.

24
00:01:16,610 --> 00:01:19,010
So this is our first instance of the GPI.

25
00:01:19,430 --> 00:01:23,400
Let it just configure it to work with the slides.

26
00:01:23,960 --> 00:01:27,920
So we'll just be naming this at light.

27
00:01:28,070 --> 00:01:28,420
OK.

28
00:01:28,970 --> 00:01:31,340
And then we customize it.

29
00:01:32,570 --> 00:01:39,170
To work with the Slater, right, so we'll be utilizing only a single channel to go ahead, do a custom

30
00:01:39,170 --> 00:01:40,970
and select switch for.

31
00:01:41,450 --> 00:01:44,780
We also need to enable an to click OK.

32
00:01:44,960 --> 00:01:49,040
And then we need to add one more instance which will be working with the push button, right?

33
00:01:49,040 --> 00:01:53,030
So you can just copy this and pasted over here, right?

34
00:01:53,630 --> 00:01:56,480
And let me just name this as push button, right?

35
00:01:56,480 --> 00:01:57,740
So button.

36
00:01:58,250 --> 00:02:00,290
And then we need to customize.

37
00:02:00,290 --> 00:02:02,930
It says that it work with the push, right?

38
00:02:02,930 --> 00:02:07,380
So we go to the GPO Channel one and then we select part and fullback.

39
00:02:07,400 --> 00:02:11,720
We also need to enable and right now we have into from two APIs.

40
00:02:11,750 --> 00:02:16,700
One of them is slates which IP and there will be a button IP, right?

41
00:02:16,700 --> 00:02:24,170
So now we need to also enable the port, which will be sensing and into from a particular library so

42
00:02:24,470 --> 00:02:26,750
that we go to a processing system.

43
00:02:27,110 --> 00:02:27,940
Customizable.

44
00:02:27,950 --> 00:02:28,380
OK, OK.

45
00:02:28,400 --> 00:02:31,540
We go to an intro and we enable fabric and prep.

46
00:02:31,550 --> 00:02:35,810
So this will be from peer to peer so we can just go in there and enable Inayat.

47
00:02:35,960 --> 00:02:38,390
Right now, you could see we have a single port.

48
00:02:38,450 --> 00:02:40,610
OK, very good for you to multiple interrupt.

49
00:02:40,610 --> 00:02:47,630
And whenever you have a multiple sources, OK, so you need to add an intermediate contact Typekit where

50
00:02:47,630 --> 00:02:52,940
you'll be feeding all danger to the input of open get IP and then output off the call and get IP will

51
00:02:52,940 --> 00:02:54,300
be feeding to an AI, right?

52
00:02:54,350 --> 00:02:56,090
So let's just click on this plus button.

53
00:02:56,570 --> 00:02:58,030
Select content.

54
00:02:58,430 --> 00:03:06,680
OK, now since you only have intro from two APIs, OK, so the default input port, which are two,

55
00:03:06,680 --> 00:03:08,390
are sufficient for our state.

56
00:03:08,390 --> 00:03:13,370
So we'll just be selecting for Studentship, connecting it to one of the code of and can get IP.

57
00:03:13,400 --> 00:03:19,730
Similarly, second intro about connecting to the second and then all contact, right?

58
00:03:20,830 --> 00:03:23,490
Then they'll put off a call and get IP will be connecting to an.

59
00:03:24,040 --> 00:03:24,340
Right.

60
00:03:24,610 --> 00:03:28,480
So this is how we will be handling a situation when we have a multiple enterprise.

61
00:03:28,490 --> 00:03:34,270
So in a case, if you have to then to enter, you just need to customize the contact block by double

62
00:03:34,270 --> 00:03:38,160
clicking on it and then choose the number of work, depending on the requirement that you have.

63
00:03:38,390 --> 00:03:40,720
So this support up to 128GB.

64
00:03:41,080 --> 00:03:41,440
OK.

65
00:03:41,680 --> 00:03:44,230
So you could vary this from one to 21.

66
00:03:44,680 --> 00:03:51,510
Right now, we proceed and connect the slave interface that we have on both Davis to the master interviews

67
00:03:51,520 --> 00:03:52,840
optic processing system, right?

68
00:03:53,140 --> 00:03:55,310
And we will do that automatically for us.

69
00:03:55,330 --> 00:03:59,320
We just need to click on connection automation, select all the ports and then click.

70
00:04:00,800 --> 00:04:01,070
Right.

71
00:04:01,130 --> 00:04:07,280
We have a zinc processing system that is connected to enemy zero caught utilizing any saying they're

72
00:04:07,300 --> 00:04:10,040
going to get to the slave interface or gold type.

73
00:04:10,190 --> 00:04:14,690
We also have connected both danger to a concrete IP and we feed that when I write.

74
00:04:14,930 --> 00:04:20,870
So this will be our block design for demonstration of how you use our multiple interest rate.

75
00:04:21,290 --> 00:04:24,440
So we have a few words in our design deuterium fixed.

76
00:04:24,440 --> 00:04:27,800
They are already connected to their respective open and switch and button.

77
00:04:28,010 --> 00:04:32,870
Since this, I recognize automatically by and we will have an automatic heart rate connection rate.

78
00:04:32,870 --> 00:04:37,570
If you go to a boat that you could actually verify, that does have any logic, right?

79
00:04:37,610 --> 00:04:43,010
This basically signifies that both of this pool that is button and switch are already connected to their

80
00:04:43,010 --> 00:04:44,110
respective hardware.

81
00:04:44,330 --> 00:04:49,400
Rachel says this isn't just reality are designed to make sure that all the magnetic reconnection are

82
00:04:49,400 --> 00:04:50,750
made to their respective open.

83
00:04:52,090 --> 00:04:57,690
I want validation is successful, right, we go ahead and the Danish build up, right.

84
00:04:58,990 --> 00:05:04,240
Now, since all the polls are been already mapped, the respect to how will you just need to go ahead

85
00:05:04,240 --> 00:05:07,180
and generate a bit steam for higher wages?