Hello.
1

2
00:00:22,230 --> 00:00:28,680
In this video we are going to learn plc communication connection ports all models excepted DVPSS2
2

3
00:00:28,680 --> 00:00:35,010
SS2 series supports left expansion models communication with different communication protocols
3

4
00:00:35,040 --> 00:00:41,280
such as Canopen Ethernet Devicenet can be provided with the left supported modules, Left supported
4

5
00:00:41,280 --> 00:00:49,320
modules or left expansion modules means we can put our special modules to right side plc like this
5

6
00:00:49,860 --> 00:00:58,410
but to left side of the plc special modules can be connected to left side modules then we can say
6

7
00:00:58,620 --> 00:01:07,260
left expansion modules then we can put here canopen ethernet , devinet modules and etc. so without
7

8
00:01:07,440 --> 00:01:17,220
or accept SS2 series another plcs can support left expansion modules and mini usb ports
8

9
00:01:17,250 --> 00:01:24,210
are all available for program upload and download an online monitoring in this table you can see for
9

10
00:01:24,270 --> 00:01:32,040
SS2 Plc model Com1 and Com2 RS232-485 communication
10

11
00:01:32,040 --> 00:01:42,240
that just two port is supported by SS2 series models for SE for example com1 is not supported
11

12
00:01:42,270 --> 00:01:50,400
but RS485 communication via com2 and rs485 communication via com3 and ethernet communication
12

13
00:01:50,400 --> 00:01:57,900
and mini usb communication is supported for example you are connecting to your plc via point
13

14
00:01:57,900 --> 00:02:09,500
to point I mean RS232 communication cable we are here but you have SE plc model.
14

15
00:02:09,550 --> 00:02:10,850
So what will happen.
15

16
00:02:10,940 --> 00:02:22,770
Need IFD converter it is converter from RS232 to RS485 communication so 
16

17
00:02:22,770 --> 00:02:23,590
rs485
17

18
00:02:23,590 --> 00:02:32,920
Communication is under the plc just to cable can connect to RS485 two wire cabling and two wire communication
18

19
00:02:33,250 --> 00:02:37,470
so you can see the cable models in here completely.
19

20
00:02:37,540 --> 00:02:47,010
So from RS232 communication you can put HMI, you can put your Pc. Also but via RS485
20

21
00:02:47,050 --> 00:02:53,910
port you can put your PC. and also for communication that is RS485
21

22
00:02:53,920 --> 00:03:01,120
you need to connect with your slaves for example in the project so you will connect to complete slaves
22

23
00:03:01,120 --> 00:03:11,950
to your RS485 and you will put your cable or programming cable to your plc via RS232 communication
23

24
00:03:12,390 --> 00:03:16,270
port so this is the communication connection ports for the plcs.
24

25
00:03:16,270 --> 00:03:19,100
This table shows us as this.
25

26
00:03:19,150 --> 00:03:26,920
This table is a guide for us and also you need to know these cables can be useful for the communications
26

27
00:03:27,190 --> 00:03:35,500
you can see them all in here it's starting from a UC and M.S. and continue so I am finished for this
27

28
00:03:35,500 --> 00:03:37,570
video see you in the next video.