1
00:00:07,460 --> 00:00:18,650
Hello, in this video, we are going to learn the FTL Akron Motor Drive, and this is our we FTL drive

2
00:00:18,830 --> 00:00:21,340
and what we hear we have in here.

3
00:00:21,470 --> 00:00:24,070
Let's make it bigger, a little bit more for you.

4
00:00:24,260 --> 00:00:28,610
We have here potentially potential metaphor for the drive speed.

5
00:00:28,760 --> 00:00:32,870
And in here we have control terminals, OK?

6
00:00:33,020 --> 00:00:39,010
And this device for the communication is four hundred and eighty five connection.

7
00:00:39,200 --> 00:00:42,290
And in here we have two switches.

8
00:00:42,560 --> 00:00:46,710
Let's go there and let's take a little bit more closer.

9
00:00:46,970 --> 00:00:49,710
OK, you can see the in here.

10
00:00:49,880 --> 00:00:59,200
So these are relay contacts and 24 volt and this is M I want an M I three and two and four and five.

11
00:00:59,450 --> 00:01:06,580
These are the control inputs and we have ten volt and what we have the rest of all Abia.

12
00:01:06,600 --> 00:01:09,830
I am a f m not ACM.

13
00:01:10,070 --> 00:01:15,560
So these are all completely explained in our manual.

14
00:01:15,740 --> 00:01:21,800
I will go down a little bit more and we will take a look once to one by one.

15
00:01:22,060 --> 00:01:33,200
OK, first of all, you can see in here our connections and this is for the factory default connections.

16
00:01:33,410 --> 00:01:44,090
If I put 24 to M, I want from here you can see digital signal come on command and DCM is here and from

17
00:01:44,090 --> 00:01:54,410
here and m I want its forward and stop and šemeta is reverse and stop inputs for these vds and what

18
00:01:54,410 --> 00:01:59,390
we have the rest of all, we will take a look once from here.

19
00:01:59,840 --> 00:02:04,000
OK Alii analog voltage input.

20
00:02:04,220 --> 00:02:12,870
OK, this is analog voltage comes from V and RF and analog output matter in here and Asia.

21
00:02:13,010 --> 00:02:21,140
Analog control signal for it is a common input and ten volt is plus potential metered power supply.

22
00:02:21,470 --> 00:02:31,570
And rest of all, what we have the context and we can see them all in here are A and R, B and RC.

23
00:02:32,000 --> 00:02:36,560
These are our asynchronous drive inputs.

24
00:02:36,950 --> 00:02:44,180
The rest of all we have in here are an S and P, so our drive is Monifa.

25
00:02:44,450 --> 00:02:52,480
So two hundred and twenty volt AC is connected to cable is connected to here and in here we have U,

26
00:02:52,790 --> 00:03:04,220
V and W these three output is for the motors and we will put motor to this output U, V and W and our

27
00:03:04,220 --> 00:03:05,840
motor will be controlled.

28
00:03:05,840 --> 00:03:07,940
Our have this ok.

29
00:03:08,090 --> 00:03:13,790
The rest of all what we have in here, let's make it a little bit more clear.

30
00:03:13,820 --> 00:03:15,170
I will try it.

31
00:03:16,620 --> 00:03:17,400
For you.

32
00:03:19,200 --> 00:03:19,930
Not OK.

33
00:03:21,430 --> 00:03:23,260
A little bit more try.

34
00:03:27,550 --> 00:03:29,790
Doesn't matter, make it bigger.

35
00:03:35,510 --> 00:03:39,170
And the this is our Ron.

36
00:03:40,690 --> 00:03:44,680
OK, and this is our stop, OK?

37
00:03:44,830 --> 00:03:52,180
The red one, and here we can increase for cancer and we can decrease and for cancer and we can go up

38
00:03:52,180 --> 00:03:57,000
or down with these two, um, these two button.

39
00:03:57,220 --> 00:04:01,470
And in here we have multipotent and this is enter.

40
00:04:01,660 --> 00:04:03,280
So it's OK button.

41
00:04:03,520 --> 00:04:11,540
And then let's try once to reset to factories that this we have this and also for Delta Wafty.

42
00:04:11,680 --> 00:04:21,560
If I press mode we will say uh we will see H and A and you and forward and frequency.

43
00:04:21,820 --> 00:04:30,070
So from here we can see the output frequency and how many amper pulls on part of our motor.

44
00:04:30,630 --> 00:04:38,230
We will go a little bit more and this is our voltage and it's forward or reverse and the turning direction

45
00:04:38,230 --> 00:04:42,200
of the motor and our set point frequency.

46
00:04:42,490 --> 00:04:45,660
So let's go to our menu firstly.

47
00:04:46,730 --> 00:04:50,740
And I will go to parameters first and let's go.

48
00:04:50,750 --> 00:04:56,790
Also, we can see them all in here, how to operate the digital carpet, but it doesn't matter.

49
00:04:57,080 --> 00:05:00,840
I will go down and down and down in here.

50
00:05:01,100 --> 00:05:02,270
Perimeter reset.

51
00:05:02,510 --> 00:05:04,590
So what will happen?

52
00:05:04,970 --> 00:05:08,450
For example, I will go to Mode and I will say enter.

53
00:05:08,450 --> 00:05:10,560
And it is perimeter zero.

54
00:05:10,580 --> 00:05:12,800
Now we are in zero and with the up.

55
00:05:14,150 --> 00:05:21,980
But I will go to two point zero zero, so two point zero zero is three now, and I will go to two point

56
00:05:21,980 --> 00:05:30,020
zero zero now of first muster for command is selected as four hundred and eighty five communication.

57
00:05:30,260 --> 00:05:41,000
And if I go to here and I go zero zero point zero two and again mode and again mode and I will go down

58
00:05:41,000 --> 00:05:45,110
and zero zero and I will go up and one more up.

59
00:05:45,360 --> 00:05:52,660
OK, this is not zero and I will reset the whole parameters to factory settings according to 50 heads.

60
00:05:52,700 --> 00:05:54,470
OK, and I will make it.

61
00:05:57,710 --> 00:06:00,690
And I will say, OK, now it's ended now.

62
00:06:00,920 --> 00:06:10,040
It is 50 years and now it is factory revisited and you can hear maybe the fun is working.

63
00:06:10,310 --> 00:06:16,340
OK, then while the fun is working, let's go to fun parameter in here.

64
00:06:17,230 --> 00:06:18,340
I will put here.

65
00:06:19,330 --> 00:06:21,970
Fun, fun is always on why?

66
00:06:21,970 --> 00:06:25,490
Because parameter three point eight is zero.

67
00:06:25,720 --> 00:06:28,750
I will go to parameter three point.

68
00:06:30,240 --> 00:06:30,870
Eight.

69
00:06:30,940 --> 00:06:39,570
OK, you can see now it's zero, and I will say if the AC motor drives runs, then that moment should

70
00:06:39,570 --> 00:06:45,110
be on and I will make it to no one stopped and I will go back.

71
00:06:45,480 --> 00:06:50,020
Now, it's 50 years and we already saw two point zero zero three.

72
00:06:50,040 --> 00:06:53,550
But now you can see two point zero zero is.

73
00:06:54,570 --> 00:06:55,050
Zero.

74
00:06:55,290 --> 00:07:04,380
OK, this is the introduction of the Delta V and the FTL series, and in the next video we will adopt,

75
00:07:04,380 --> 00:07:11,880
uh, four see this potential amateur and with these buttons up and down and also we will use, um,

76
00:07:11,880 --> 00:07:15,260
we will learn acceleration and deceleration times and etc..

77
00:07:15,570 --> 00:07:16,950
I have finished for this video.

78
00:07:17,130 --> 00:07:18,970
See you in the next video.

79
00:07:18,990 --> 00:07:20,640
OK, see you.