1
00:00:13,880 --> 00:00:14,810
These students.

2
00:00:14,810 --> 00:00:23,730
In this tutorial I am going to talk about how can we communicate with Omron CPU and delta HDMI?

3
00:00:23,900 --> 00:00:27,590
This is my omron CPU one e CPU.

4
00:00:27,590 --> 00:00:29,510
And then here I am.

5
00:00:29,510 --> 00:00:40,520
I have the p-series HDMI and here you can see five and on my computer let's go there and here I am selecting

6
00:00:40,730 --> 00:00:48,620
the five data register and into my program you will see this is five and I will change it.

7
00:00:48,620 --> 00:00:49,700
Let's change it together.

8
00:00:49,700 --> 00:00:54,050
For example, 25 and now it's 25.

9
00:00:54,080 --> 00:00:55,220
You can see it.

10
00:00:55,220 --> 00:00:57,290
And on the Omar it's 25.

11
00:00:57,290 --> 00:00:59,810
So what is the trick between it?

12
00:01:00,410 --> 00:01:08,350
And I will come to here and you will see the settings section and here you will see serial option part.

13
00:01:08,360 --> 00:01:17,930
This is custom I selected and this is also the same OC 7e11 or 9600 default.

14
00:01:17,930 --> 00:01:23,390
Okay, this is my selection for the omron side and for the data side.

15
00:01:23,390 --> 00:01:29,120
Let's go to Delta and here I'm going to go to options section and into configuration.

16
00:01:29,120 --> 00:01:32,300
No, sorry, into communication settings.

17
00:01:32,300 --> 00:01:32,960
Okay.

18
00:01:32,960 --> 00:01:38,900
We have RS 405 port on Comm two for this HMI.

19
00:01:38,930 --> 00:01:45,800
This is the P series five inch HDMI and here I selected manufacturer's omron and here you will see CPU

20
00:01:45,800 --> 00:01:49,220
one, C, A, C, G and C and KVM.

21
00:01:49,220 --> 00:01:55,430
And here you can see R is 485 7 to 9611.

22
00:01:55,430 --> 00:01:59,960
Okay, this is my communication parameter on the high side.

23
00:01:59,960 --> 00:02:06,380
So what we have another thing, the high side is okay and also Omron side is okay.

24
00:02:06,380 --> 00:02:09,260
I already shocked to hear the settings section.

25
00:02:09,260 --> 00:02:09,840
Okay.

26
00:02:09,950 --> 00:02:14,030
And what we need, we need the communication cable on the omron.

27
00:02:14,420 --> 00:02:21,050
Here you will see this green connection point and here you have a minus B plus.

28
00:02:21,050 --> 00:02:24,200
This is the average 485 communication port.

29
00:02:24,200 --> 00:02:35,090
And here you will see my computer on computer the green cable is empty and just white cable and the

30
00:02:35,090 --> 00:02:36,710
brown cable is connected.

31
00:02:36,710 --> 00:02:38,300
And here you will see.

32
00:02:39,050 --> 00:02:40,790
Let's go close a little bit more.

33
00:02:41,000 --> 00:02:43,670
And one and six is connected.

34
00:02:43,670 --> 00:02:44,420
Okay.

35
00:02:44,720 --> 00:02:46,640
And let's make it clear for you.

36
00:02:46,640 --> 00:02:56,180
And here the brown one is connected to six and the white one is connected to one, one and six.

37
00:02:56,180 --> 00:03:01,160
So these two cable four is 488 five.

38
00:03:01,160 --> 00:03:07,490
Communication Part one and six is connected A minus two, B plus.

39
00:03:07,490 --> 00:03:10,220
So this is my communication cable.

40
00:03:10,220 --> 00:03:17,240
And let's make it clear for you and the settings between and settings area in the six program and also

41
00:03:17,240 --> 00:03:21,530
communication parameters on the top soft side of the Delta HMI.

42
00:03:21,560 --> 00:03:31,220
And then this is communicated and how we know it's communicating here or is 485 is now flashing is orange.

43
00:03:31,220 --> 00:03:35,930
Okay, this is the communication between Delta II and Omron plc.

44
00:03:35,960 --> 00:03:37,880
For this tutorial I am finished here.

45
00:03:37,880 --> 00:03:39,600
See you into next period.