0
1
00:00:21,540 --> 00:00:22,320
Hello.
1

2
00:00:22,350 --> 00:00:27,430
In the previous lessons we learned how to go online to plcs via
2

3
00:00:27,450 --> 00:00:29,090
rs232
3

4
00:00:29,090 --> 00:00:30,990
Communication in this video.
4

5
00:00:30,990 --> 00:00:31,980
Let's take a look.
5

6
00:00:31,980 --> 00:00:37,440
How to Start simulator in ISPsoft
6

7
00:00:37,550 --> 00:00:46,790
I will create the new project and I will give simulator a name to my project controller type will be
7

8
00:00:46,790 --> 00:00:47,820
ss2
8

9
00:00:48,080 --> 00:01:01,500
And let's say ok new project is created and I will go to program section a new and simulatorworks .
9

10
00:01:01,500 --> 00:01:03,430
I will say it like this.
10

11
00:01:03,450 --> 00:01:07,520
Leave it like this and say okay let this here.
11

12
00:01:07,680 --> 00:01:12,380
LD m5 and out Y5.
12

13
00:01:12,840 --> 00:01:22,210
So now in communication settings what we have just the serial communication in commgr.
13

14
00:01:22,240 --> 00:01:23,150
You can see it.
14

15
00:01:23,140 --> 00:01:30,040
We add serial communication as rs232/485/422
15

16
00:01:30,040 --> 00:01:31,030
Communication.
16

17
00:01:31,030 --> 00:01:34,390
But I want to add or I want to use simulator.
17

18
00:01:34,390 --> 00:01:45,850
Come here click add button in connection setup area you will see a DVP simulator an AH5x1
18

19
00:01:45,880 --> 00:01:56,080
simulators but our cpu is DVP14SS2 CPU,I will select DVP simulator and in here
19

20
00:01:56,080 --> 00:01:59,070
Device settings you need to select correct.
20

21
00:01:59,110 --> 00:02:08,760
CPU , our cpu is ss2  too so I am selecting this and I am saying Okay now our driver1  simulator
21

22
00:02:08,770 --> 00:02:16,020
driver is stopped but serial communication is started I will come here to driver1 so that means dvp
22

23
00:02:16,020 --> 00:02:23,280
simulator and I will say start and now  it is started.
23

24
00:02:23,440 --> 00:02:34,420
So for a moment these drivers started but this is not for to make it stop in software
24

25
00:02:34,770 --> 00:02:36,370
we will select to now
25

26
00:02:39,100 --> 00:02:41,580
simulator in here come here.
26

27
00:02:41,580 --> 00:02:50,410
Tools communication settings and you can see it now driver1. So this is our simulator in here I said
27

28
00:02:50,470 --> 00:02:54,220
okay again I will show to you communication settings.
28

29
00:02:54,220 --> 00:03:04,450
DRIVER 1 is selected.Driver 1 is simulator I will say okay again in here you can see the simulator 
29

30
00:03:05,110 --> 00:03:12,230
area but have to go online to simulator this is just similar with the wplsoft
30

31
00:03:12,280 --> 00:03:19,720
But this is DCIsoft for the ISPsoft ,you need to come here you need to say online mode.program has not been
31

32
00:03:19,720 --> 00:03:28,030
compiled and I will say Okay now it's compiling and now it is going to send this project to simulator
32

33
00:03:28,300 --> 00:03:36,550
but where we know or where do we get this information which cpu that we connected simulator or
33

34
00:03:36,550 --> 00:03:44,980
like ss2 or another one in here you can see Driver 1 DVP simulator that you can see in here and also
34

35
00:03:44,980 --> 00:03:47,220
in here you can see the simulator.
35

36
00:03:47,320 --> 00:03:55,660
So we can connect to a simulator with like this and also now we connected to simulator come
36

37
00:03:55,660 --> 00:04:04,560
here set on and set off so we can simulate our plc projects with like this.
37

38
00:04:04,600 --> 00:04:08,350
So I am finished in this video see you in the next video.
