0
1
00:00:21,310 --> 00:00:22,190
Hello.
1

2
00:00:22,260 --> 00:00:28,790
In this video we are going to learn what is PLC and what is the delta PLC.
2

3
00:00:28,850 --> 00:00:39,870
DVP models PLC as basically programmable logic controllers are programmable control devices that
3

4
00:00:40,160 --> 00:00:48,230
process the information from the inputs in the program written in the CPU and operate the devices connected
4

5
00:00:48,240 --> 00:00:50,600
to their outputs as desired.
5

6
00:00:50,880 --> 00:01:01,230
So we have a PLC we have are IOs and also we have outputs so inputs according to our inputs.
6

7
00:01:01,600 --> 00:01:13,630
CPU This is our CPU ,so CPU is processing information inside of it and it is giving and outputs
7

8
00:01:13,990 --> 00:01:23,290
and connected output devices is desired according to programmer according to who designed the PLC
8

9
00:01:23,290 --> 00:01:31,000
programs and etc. so we can say it with the fast developing technology PLCs are logic controller
9

10
00:01:31,120 --> 00:01:35,920
devices that it is used in the wider control area.
10

11
00:01:35,920 --> 00:01:44,740
Integrated with analog control position control and different communication systems so different communication
11

12
00:01:44,740 --> 00:01:53,380
systems means we can use modbus, profinet, profibus ,ethercat, canopen an Internet IP Communications
12

13
00:01:53,800 --> 00:02:04,030
as basically and these are really popular and the common communication mode communication techniques
13

14
00:02:04,120 --> 00:02:13,330
in the industrial area but for delta PLCs modbus is the very very common and for example for
14

15
00:02:13,330 --> 00:02:22,180
the delta plcs  if you need to use a profibus communication you need to add extra special modules but
15

16
00:02:22,180 --> 00:02:28,460
the important thing of this video you must learn also we need to understand this.
16

17
00:02:28,570 --> 00:02:39,610
CPU or plcs are reacting according to inputs and assigning or changing to outputs according to
17

18
00:02:39,880 --> 00:02:45,120
inputs.ınputs is really important for the CPU and
18

19
00:02:45,490 --> 00:02:55,690
According to this inputs and according to our programs CPU is changes its own outputs so plcs are
19

20
00:02:55,990 --> 00:03:08,020
working like this DVP series PLC models is that DVP SS2 so SS means slim and standard SA2 - SA
20

21
00:03:08,230 --> 00:03:18,610
slim and advanced SA means slim and Internet communication and sx2 slim analog and sv2
21

22
00:03:18,610 --> 00:03:27,550
to slim high performance so the names are coming slim standard advanced for Internet and analog and
22

23
00:03:27,670 --> 00:03:36,040
performance but in here we can just immediately check in what what is the plc structure you can see
23

24
00:03:36,100 --> 00:03:36,580
in here.
24

25
00:03:36,580 --> 00:03:43,930
is it powered or not or  is it run situation or not or is it giving an error or not.
25

26
00:03:43,930 --> 00:03:51,580
These these are the LEDs and this is SS our common cable can connect here and you must connect it to
26

27
00:03:51,580 --> 00:03:54,310
here and x0 to x7.
27

28
00:03:54,310 --> 00:04:03,430
These are inputs as physical and this is Up-Zp, This is a transistor output plc so we need to put
28

29
00:04:03,430 --> 00:04:05,690
in here 24Vdc and 0vdc.
29

30
00:04:05,750 --> 00:04:08,980
And in here we will get our outputs.
30

31
00:04:09,010 --> 00:04:14,500
And here you can see run and stop switch .So we can change.
31

32
00:04:14,500 --> 00:04:25,720
CPU situation from run to stop or stop to run with this switch and in here for example this black
32

33
00:04:25,780 --> 00:04:27,040
area the circle.
33

34
00:04:27,040 --> 00:04:33,880
This is rs232 communication point so we can go on line or connect to plc
34

35
00:04:34,150 --> 00:04:44,440
with our own computer from here and under the PLC you're going to see a for 485 communication socket
35

36
00:04:44,530 --> 00:04:54,180
or connection point for example DVP 28SV , this is we have power led and run led an error
36

37
00:04:54,180 --> 00:05:00,490
led and also battery low led and in here also rs232 and rs485 communication
37

38
00:05:00,490 --> 00:05:09,010
leds while it's communicating these leds are flashing and in here relay output c0 ,c1 these are
38

39
00:05:09,280 --> 00:05:13,480
should be 24 volt and common because what we need.
39

40
00:05:13,550 --> 00:05:20,800
from output what we need to get from output zero Volt or 24v we need to put or connect
40

41
00:05:20,800 --> 00:05:31,510
these voltage value to our outputs common point and in here you can see run and stop switch in here and
41

42
00:05:31,510 --> 00:05:42,080
also connection point of plc and inputs and outputs and the common points and other inputs and you
42

43
00:05:42,080 --> 00:05:51,680
can see while the our models are changing a little bit structure is also changing the how can I say
43

44
00:05:51,930 --> 00:05:57,860
it is giving a lot of opportunity to us in here for example we can use
44

45
00:06:00,710 --> 00:06:04,780
16 input and also in here.
45

46
00:06:04,990 --> 00:06:16,460
I'm counting two four six and eight and twelve output in just one CPU and in here for the SS2 we
46

47
00:06:16,480 --> 00:06:21,580
have just eight input and just six output.
47

48
00:06:21,580 --> 00:06:30,610
So for example you need more than eight input and more than six output and just you want to buy one
48

49
00:06:30,670 --> 00:06:37,870
CPU according to DCP series plc models of the Delta, you can select this one or this one and
49

50
00:06:37,870 --> 00:06:41,680
this one but this is already up to you.
50

51
00:06:41,710 --> 00:06:45,680
This is just an introduction video  So for a moment.
51

52
00:06:45,720 --> 00:06:46,930
I am finished here.
52

53
00:06:46,930 --> 00:06:48,510
See you in the next video.