0
1
00:00:21,890 --> 00:00:23,310
Hello in this video.
1

2
00:00:23,320 --> 00:00:28,230
We are going to learn how to do an online edit for Delta plcs.
2

3
00:00:28,290 --> 00:00:32,880
Let's create a new project and let's give it to name online.
3

4
00:00:33,130 --> 00:00:35,080
edit, our Plc type is.
4

5
00:00:35,080 --> 00:00:37,360
ss2  I'm saying okay.
5

6
00:00:38,750 --> 00:00:42,550
new project is created in programs area.
6

7
00:00:42,560 --> 00:00:48,200
I will say right click a new and online edit and.
7

8
00:00:48,350 --> 00:01:01,710
Okay this project is created and let's create the basic project LD M10 and out M11. Okay , 
8

9
00:01:02,310 --> 00:01:08,990
I will use this auxiliary relays in this project and let's send it to our plc now
9

10
00:01:09,120 --> 00:01:17,870
It's transferring and we are using a serial communication with the existing one and real one plc.
10

11
00:01:17,870 --> 00:01:24,970
Now it's transferring we are not using a simulator for this project and go back to running state and
11

12
00:01:25,180 --> 00:01:26,050
it's finished.
12

13
00:01:26,290 --> 00:01:31,200
So I will go online to my plc and I will check.
13

14
00:01:31,210 --> 00:01:31,550
OK.
14

15
00:01:31,560 --> 00:01:36,880
We have a run situation and I will say set on and set off.
15

16
00:01:37,080 --> 00:01:37,520
OK.
16

17
00:01:37,540 --> 00:01:38,200
This is OK.
17

18
00:01:38,200 --> 00:01:41,940
This is working and everything seems good for a moment.
18

19
00:01:41,950 --> 00:01:49,390
So now imagine you have a machine and this machine is working very high efficiency and producing a lot
19

20
00:01:49,390 --> 00:01:55,220
of material and you cannot stop this machine you cannot stop any moment.
20

21
00:01:55,420 --> 00:01:56,980
And you need to change.
21

22
00:01:56,980 --> 00:01:57,820
One more thing.
22

23
00:01:57,820 --> 00:02:06,220
For example one output that you need change or you need to add extra one more inputs or outputs to your
23

24
00:02:06,220 --> 00:02:09,350
plc project or to your machine.
24

25
00:02:09,370 --> 00:02:14,080
How can you do this ?  In Delta plcs in ISPSoft software.
25

26
00:02:14,290 --> 00:02:16,250
You will see in here on line.
26

27
00:02:16,280 --> 00:02:16,950
Edit Mode.
27

28
00:02:17,140 --> 00:02:22,120
You need to click this and after you click this you will see.
28

29
00:02:22,210 --> 00:02:23,120
This is online.
29

30
00:02:23,140 --> 00:02:31,060
Edit mode will be activated and you can come here and you can add for example one more output Y1
30

31
00:02:31,060 --> 00:02:38,060
to here and one more extra network LD M20.
31

32
00:02:38,070 --> 00:02:46,650
Lets say you need to add imagine one timer you edit your changes to your project.
32

33
00:02:46,660 --> 00:02:47,850
You need to come here.
33

34
00:02:47,860 --> 00:02:54,970
You need to say online update and recommended redownload program after finish this operation I'm
34

35
00:02:54,970 --> 00:02:57,640
saying okay update the program line.
35

36
00:02:57,670 --> 00:03:01,370
Okay now update is completed.
36

37
00:03:01,450 --> 00:03:08,410
So for a moment we send our changes to plc.
37

38
00:03:08,710 --> 00:03:17,560
If we try to send again there is nothing to change then this will helps to change or do an update
38

39
00:03:17,560 --> 00:03:22,300
or online changes in your plc projects or in your machines.
39

40
00:03:22,450 --> 00:03:23,550
with like this.
40

41
00:03:23,770 --> 00:03:30,000
And one more thing in here you can see set MPU X on and off.
41

42
00:03:30,490 --> 00:03:40,400
I will go offline and I will start my simulator, it started and this is an extra information
42

43
00:03:40,400 --> 00:03:48,800
for this video and I will change my in my tools communications settings and Driver 1 is selected for
43

44
00:03:48,800 --> 00:03:51,190
example LD X1.
44

45
00:03:51,200 --> 00:03:52,690
This is sensor input.
45

46
00:03:52,700 --> 00:04:03,680
Imagine sensor input and out Y5 okay.
46

47
00:04:03,810 --> 00:04:13,230
Now I will go online and simulator is going to be started and now simulator is started.
47

48
00:04:13,260 --> 00:04:19,240
But we need to send this project to our simulator and simulator is stopped now.
48

49
00:04:19,320 --> 00:04:27,530
In here you can see it , plc run confirmed and now we have run situation X0
49

50
00:04:27,540 --> 00:04:32,030
I am saying activate than you can see.
50

51
00:04:32,060 --> 00:04:42,830
Communication error function not supported and I will come here said MPU X and on and off and in here.
51

52
00:04:42,890 --> 00:04:54,110
Now you can see we can activate its inputs physical inputs with this selection so you can set MPU or
52

53
00:04:54,520 --> 00:05:03,860
CPUs , X areas or X points on and off you can allow this than after you select this in your simulator or
53

54
00:05:03,860 --> 00:05:10,380
in your projects you can activate or disactivate X inputs with like this.
54

55
00:05:10,380 --> 00:05:18,590
So this is really another one important while you are working or learning delta PLC while you are trying
55

56
00:05:18,590 --> 00:05:28,210
to simulate some programs or projects when your X inputs used in the projects you need to maybe you
56

57
00:05:28,210 --> 00:05:31,210
you may need to activate these X inputs.
57

58
00:05:31,220 --> 00:05:33,540
This is an extra information for you.
58

59
00:05:33,620 --> 00:05:36,020
You can use it with like this.
59

60
00:05:36,110 --> 00:05:38,340
So I am finished in this video.
60

61
00:05:38,360 --> 00:05:39,800
See you in the next video.