1
00:00:10,000 --> 00:00:12,000
Good morning, friends, good day.

2
00:00:13,000 --> 00:00:25,000
I will tell you how to grab the data of multiple variables in LabView and then we have to observe the

3
00:00:25,000 --> 00:00:31,000
data using I'll be using things like application.

4
00:00:32,000 --> 00:00:34,000
We can observe this data.

5
00:00:35,000 --> 00:00:46,000
OK, so for that purpose, I just go to speak and over here you have to first login yourself back as

6
00:00:46,000 --> 00:00:47,000
I login in this.

7
00:00:48,000 --> 00:00:56,000
I already told you how to login in my previous video, then create a new channel or here this is my

8
00:00:56,000 --> 00:00:57,000
new channel.

9
00:00:58,000 --> 00:01:02,000
So let the name of this parameter.

10
00:01:05,000 --> 00:01:10,000
Right now, I just used to barometer's and over here, this is temperature

11
00:01:14,000 --> 00:01:16,000
and humidity,

12
00:01:19,000 --> 00:01:20,000
guilty of my room.

13
00:01:21,000 --> 00:01:25,000
So for that purpose, I use to feel so first.

14
00:01:25,000 --> 00:01:26,000
When is my temperature?

15
00:01:29,000 --> 00:01:31,000
And second one is my community.

16
00:01:35,000 --> 00:01:45,000
So right now, this is and I just save this channel and over here there are two things.

17
00:01:46,000 --> 00:01:47,000
First one is temperature.

18
00:01:47,000 --> 00:01:48,000
Second one is.

19
00:01:49,000 --> 00:01:58,000
So as you see, first I change the settings of my channel or check my settings.

20
00:01:58,000 --> 00:02:01,000
You can also show your location.

21
00:02:02,000 --> 00:02:04,000
Right now, I'm not using this.

22
00:02:04,000 --> 00:02:05,000
Then go to the option.

23
00:02:07,000 --> 00:02:12,000
Just select Clear Channel view with everyone and just go do it.

24
00:02:14,000 --> 00:02:18,000
So this is my API for this case.

25
00:02:19,000 --> 00:02:21,000
Now I just go to my view.

26
00:02:21,000 --> 00:02:28,000
This is my block diagram window or here, just go to pick up.

27
00:02:28,000 --> 00:02:28,000
Right.

28
00:02:28,000 --> 00:02:30,000
Click and go to the communication.

29
00:02:30,000 --> 00:02:36,000
And in this of protocols right now, I'm using SCDP flying protocol.

30
00:02:36,000 --> 00:02:44,000
So just lock it up on this, get the data and close this.

31
00:02:44,000 --> 00:02:51,000
Or you can use or here a simple error handler block also.

32
00:02:52,000 --> 00:03:02,000
So just connect this connect client handle out client handle Herradura.

33
00:03:05,000 --> 00:03:19,000
Just this after this, I go to my Bilu where because I read the data continuously, so in this case

34
00:03:21,000 --> 00:03:32,000
I just go to my string over here, this is my concatenate string, then I just use the form texting

35
00:03:35,000 --> 00:03:42,000
and I just create a constant over here and over here.

36
00:03:43,000 --> 00:03:49,000
This is my AIPA request to write that.

37
00:03:49,000 --> 00:03:57,000
I just copy this, go to do or have control.

38
00:03:58,000 --> 00:04:07,000
So as earlier I said, this is my Gilady to speak English to do it.

39
00:04:07,000 --> 00:04:18,000
And the very little right now I have multiple data, so just check it out.

40
00:04:18,000 --> 00:04:20,000
I can grab the multiple data.

41
00:04:20,000 --> 00:04:23,000
So this is my MPC.

42
00:04:24,000 --> 00:04:28,000
I just close this or delete this and pull over here.

43
00:04:28,000 --> 00:04:40,000
But this is interesting for me and I just copy this and feel one and put over here multiple.

44
00:04:41,000 --> 00:04:50,000
So this is my end one and my format is in like it is impossible not to have.

45
00:04:51,000 --> 00:05:04,000
Again, this is also in Libya like this in my data, I just copy this and also or here.

46
00:05:05,000 --> 00:05:08,000
So this will get the rate of temperature.

47
00:05:08,000 --> 00:05:10,000
This will get at the rate of humidity.

48
00:05:11,000 --> 00:05:12,000
This is the format.

49
00:05:13,000 --> 00:05:22,000
And over here I just use this and I just go to my friend panel.

50
00:05:22,000 --> 00:05:25,000
And over here, this is my stream control.

51
00:05:26,000 --> 00:05:35,000
And in this I just put the MPC API key.

52
00:05:36,000 --> 00:05:38,000
So my MPC in this case.

53
00:05:39,000 --> 00:05:39,000
Right, right.

54
00:05:40,000 --> 00:05:51,000
Not read because I know I'm reading the data to the cloud, so I just copy this over here.

55
00:05:52,000 --> 00:05:55,000
So this is my MPC, as you see.

56
00:05:56,000 --> 00:06:03,000
And what here this is the temperature data and this is the humidity data for that purpose.

57
00:06:03,000 --> 00:06:10,000
I just numeric and I using this random number and I just change it to Debian.

58
00:06:11,000 --> 00:06:19,000
And the upper limit of temperature in the case of India is six degrees Celsius, maximum temperature

59
00:06:19,000 --> 00:06:22,000
and the minimum temperature is like zero degrees Celsius.

60
00:06:22,000 --> 00:06:34,000
OK, so I just connect this and for the community purposes I just copy this and I just connect this.

61
00:06:35,000 --> 00:06:42,000
And in this case, this random number will generate a different number and this random number, different

62
00:06:42,000 --> 00:06:42,000
number.

63
00:06:42,000 --> 00:06:51,000
And the reality is that a hundred degrees, not up to a hundred maximum limits and lower limit is going

64
00:06:51,000 --> 00:06:53,000
to be this is the humidity.

65
00:06:53,000 --> 00:06:56,000
So I just connect this.

66
00:06:58,000 --> 00:07:09,000
So right now the program is really for variables and or here this is the error because the stop button

67
00:07:09,000 --> 00:07:11,000
is not created for the value.

68
00:07:11,000 --> 00:07:12,000
Right now.

69
00:07:12,000 --> 00:07:17,000
The program is ready and I just run it as a redundant button.

70
00:07:18,000 --> 00:07:27,000
So as you see in the private view, the data is filtered so rare.

71
00:07:27,000 --> 00:07:34,000
This is the data at six forty six, three seconds and it will updated.

72
00:07:40,000 --> 00:07:46,000
Take some time, as you see there, it is updated, so temperature is around forty five degrees Celsius

73
00:07:46,000 --> 00:07:49,000
and humidity is 78.

74
00:07:49,000 --> 00:07:53,000
So I use would get for this.

75
00:07:53,000 --> 00:07:56,000
So there is a numeric display.

76
00:07:57,000 --> 00:07:59,000
I create a numeric display for the first one.

77
00:08:00,000 --> 00:08:01,000
This is the temperature.

78
00:08:05,000 --> 00:08:09,000
Temperature, and this is the parade and the unities degrees Celsius.

79
00:08:10,000 --> 00:08:19,000
I just with this over here, you can see the temperature data and another numerical data for the humidity.

80
00:08:24,000 --> 00:08:33,000
I just create and over here, I just selectively do so they say to the community, so as you see, the

81
00:08:33,000 --> 00:08:45,000
data is created in the system and it is updated after every second, every 15 seconds, as you see,

82
00:08:45,000 --> 00:08:48,000
647, six, 47, 15.

83
00:08:48,000 --> 00:08:53,000
After 15 seconds, it will be updated.

84
00:08:54,000 --> 00:08:56,000
It takes all the data from the lab.

85
00:08:59,000 --> 00:09:01,000
There is no delay of data.

86
00:09:02,000 --> 00:09:06,000
It will take the after every 15 minutes, 30 seconds.

87
00:09:06,000 --> 00:09:12,000
It depends on your system or here.

88
00:09:12,000 --> 00:09:13,000
This is the data.

89
00:09:13,000 --> 00:09:20,000
As you see, 59 degrees Celsius and 52 is the parameter immunity.

90
00:09:21,000 --> 00:09:29,000
So this is how you can grab the data of multiple variables, in my view, using things like thank you.
